piSmart-Gateway LC · Industrial IoT gateway and CAN bus data logger

CAN bus and sensor data from the machine, securely in your cloud

The gateway reads CAN, CANopen, voltage inputs and its own sensors on the machine, stores every value locally and sends it encrypted via MQTT or HTTPS. You can reach it from anywhere via VPN, and the battery takes over during a power failure.

The IoT shop is available in German.

  • LTE and Wi-FiConnected wherever the machine is
  • CAN and CANopenDirectly on the fieldbus, no extra hardware
  • MQTT and HTTPSEncrypted to your cloud
  • Backup batterySeveral hours without external power

Your benefits

Use machine data without modifying the machine

The piSmart-Gateway LC makes existing machines IoT-ready. It listens on the CAN bus, adds its own measurements and delivers the data to wherever you analyse it.

  • IoT retrofit for existing machines

    Upgrade instead of replace: the gateway connects to CAN or CANopen without touching the machine software.

  • Remote machine monitoring

    Keep an eye on operating states, measurements and error messages via LTE or Wi-Fi, including machines working outdoors.

  • Your data, your platform

    Standard protocols instead of a closed system: live values via MQTT with TLS, log files via HTTP or HTTPS to your own server.

  • Complete records

    Every value is also stored locally. Gaps in mobile coverage and power failures do not cause data loss.

The device

Compact and robust for mounting on the machine

The piSmart-Gateway LC comes in a compact enclosure with mounting lugs and is screwed directly onto the machine. Data sources, storage, cellular connectivity and backup battery are combined in one device.

piSmart-Gateway LC by pironex: black enclosure with red pironex lettering and mounting lugs, in front of a factory hall
piSmart-Gateway LC, image: pironex

Features

From fieldbus to cloud in one device

No server of your own and no programming required. Setup happens in the browser.

CAN bus with DBC

Capture, filter and throttle raw frames. With your DBC file, the gateway decodes selected messages into signals for the live view and MQTT.

CANopen

Configure CANopen nodes, query objects via SDO and record PDOs automatically.

Built-in sensors

Temperature, acceleration and rotation rate on board, plus two analog inputs for voltages from 0 to 24 V. For condition monitoring and vibration analysis.

LTE and Wi-Fi

Mobile network for outdoor use, Wi-Fi for the factory floor, including corporate networks with WPA2-Enterprise. The built-in access point allows initial setup without any infrastructure.

Remote access via VPN

The gateway joins your WireGuard network over LTE or Wi-Fi. You can then reach the web application from anywhere, without port forwarding on site. The device generates its own key, or you import a .conf file.

MQTT gateway with TLS

Live values via MQTT with TLS, plus the previous day's log files uploaded every night via HTTP or HTTPS to your server.

Local data backup

Every measurement is also written as CSV to internal storage, with an optional microSD card for long recordings. If the mobile network drops, nothing is lost. When storage is full, the oldest days are removed automatically.

Web application

A wizard guides you through setup, access is login-protected. Log download and firmware updates in the browser. Export a finished configuration and load it onto further devices.

Live view

Real-time measurements in the browser. Zoom and cursor are linked across all charts, and a selected range shows minimum, maximum and mean.

Fail-safe

Power failure without data loss

The backup battery bridges a loss of supply voltage. The gateway keeps working autonomously for several hours and finishes writing every record cleanly.

Several hours autonomous

Measure, store and send even when the machine is switched off.

No corrupted files

After a configurable time, the gateway closes all log files and shuts down in a controlled way. No interrupted write operations, the data remains complete and readable.

The outage is in the log

The minutes around the power failure are recorded, exactly the ones people ask about later.

Commissioning

Ready in minutes

  1. Connect

    Power supply and CAN bus to the terminals. The gateway starts on its own.

  2. Join

    Connect to the gateway's Wi-Fi and open the web application.

  3. Configure

    The wizard guides you through network, data sources and cloud destination.

  4. Analyse

    Data flows live into your platform and in parallel into local storage.

See CAN signals live in under two minutes

Open the wizard, select CAN bus, load a DBC file, tick messages, check the HTTP upload to your own server and follow the values immediately in the live view. Recorded on the device, sped up 1.2× with shortened waiting times while saving. Uncut, the process takes about 1:31. The user interface is shown in English, the overlay captions in German.

Screen recording of the web application: setup wizard with the CAN bus and Temperature modules, loading a DBC file, selecting the messages EngineData and Hydraulics, then engine speed and pump pressure running in the live view. No sound, 1:15 minutes.

Applications

For machines in tough everyday use

Mobile machinery

Monitor construction, agricultural and municipal vehicles via LTE. Operating states and error messages in one central view.

Industrial plants

Retrofit existing CANopen controllers without touching the machine software. Retrofit instead of replacement.

Predictive maintenance

Continuously capture vibration and temperature and detect wear before it leads to downtime.

Datasheet

Specifications

Developed by pironex in Germany. On request, we adapt hardware and firmware to your application.

Specifications piSmart-Gateway LC
ProcessorESP32-S3, dual core
CellularLTE Cat-M1 / NB-IoT
Wi-Fi2.4 GHz, client and access point, WPA2-Enterprise (PEAP)
FieldbusCAN with DBC decoding, CANopen (SDO, PDO)
SensorsTemperature, acceleration, gyroscope
Analog inputs2 voltage inputs, 0 to 24 V, recorded in the log
StorageInternal flash for CSV data logging, optional microSD for long recordings
CloudMQTT over TLS, daily file upload via HTTP or HTTPS
Remote accessWireGuard VPN, web application reachable via the VPN address
OperationWeb application with login, setup wizard and live view, configuration export and import
PowerBackup battery, several hours of operation without external supply, followed by controlled shutdown
UpdatesOver-the-air update with signature verification

Subject to technical changes. Detailed information for your application is available on request.

Test the gateway on your machine